SALES@SOUTHCOASTIANDC.COM (949) 218-0026

PRODUCT DESCRIPTION

The QTS Maverick In-Tank transmitter is configured with a flexible hose constructed of 316L stainless steel that can be ordered in lengths from 120 inches to 866 inches with a 4-20mA. Once installed and calibrated there is no requirement for scheduled maintenance or recalibration.

Maverick In-Tank Transmitter DIRECT INSERT TRANSMITTER

MORE INFORMATION

Most frequent questions and answers

Product Features

  • No maintenance required
  • Multidrop HART Communications
  • FM Approved Explosion Proof/IS
  • NEMA 4x/7 enclosures
  • Modular design
  • Adjustable output damping
  • Up to .001” resolution
  • 2-wire loop powered
  • RFI/EMI protection
  • Offers a 4/20 mA 2-wire loop powered circuit for continuous level measurement
  • Available up to 866 inches
  • Process temperature range: -30 to 400°F

Product Specifications

Level OutputSpecification
Measured VariableProduct level & interface level
Output Signal / Protocol4 to 20 mA with HART®, 1 or 2 Loop
Order LengthsFlexible Hose:

 

(ATEX Ex ia IIB, FM IS Group C, D):

3048 mm (120 in.) to 7620 mm (300 in.)*

 

(All Else):

3048mm (120 in.) to 12200mm (480 in.)*

 

Rigid Pipe:

508mm (20 in.) to 7620mm (300 in.)

 

Non-Linearity0.02% F.S. or 0.794mm (1/32 in)**
Repeatability0.01% F.S. or 0.381mm (0.015 in)**

(any direction)

*Contact QTS for longer lengths
**Whichever is greater

Output4-20mA HART®
Linearity0.02% F.S.
Measuring RangeRigid Pipe: 20-300 Inches Flexible Hose: 120-480 inches
ApprovalATEX, CSA, FM

 

ParametersSpecification
Enclosure RatingNEMA Type 4X
Humidity0 to 100% relative humidity, non-condensing
Operating TemperatureElectronics:

-40°C (-40°F) to 71°C (160°F)

Sensing Element:

-40°C (-40°F) to 125°C (257°F)

Temperature Element:

-40°C (-40°F) to 105°C (221°F)

Vessel PressureIndustrial Rigid Pipe: 1000 psi (69 bar)

Sanitary Pipe: 435 psi (30 bar)

Teflon Pipe: 100 psi (7 bar)

Flexible Hose: 260 psi (18 bar)

MaterialsWetted Parts: 316L stainless steel

Non-wetted Parts: 316L stainless steel

Epoxy coated aluminum

* Contact QTS for alternative material

Electronics

Input Voltage10.5 to 36 VDC, 28 VDC Max. for I.S. Approval
Fail SafeHigh (21.4mA) or Low (3.8 mA)
Reverse Polarity ProtectionSeries diode
Light/Transient ProtectionStage 1:

Line-to-ground surge suppression; IEC 61000-4-5

 

Stage 2:

Line-to-ground surge and line-to-ground transient suppressors, IEC 61000-4-4

Wiring

Connections2-wire shielded cable or twisted pair, Daniel Woodhead 6-pin male connector, 4570 mm (180 in) integral cable with pigtail

Calibration

Zero Adjust RangeAnywhere within active length
Span Adjust RangeFull Scale to 152 mm (6in.) from zero

Mounting

Rigid Pipe¾” in. adjustable MNPT fitting Flange or Ti-Clamp® Mount
Flexible Hose1” in. adjustable MNPT fitting Flange Mount

Electrical Connections

Single & Dual Cavity¾” in. FNPT conduit opening
NEMA Type 4X½” in. FNPT conduit opening

Display

Measured VariablesProduct level, interface
VariablesLevel and temperature
Size13 mm (0.5 in)
Number of Digits16

Documents

DocumentTitleCategory
400-02Maverick OverviewProduct Literature
430-04MTS Magnetostrictive Transmitter IOMIOMs

Get In touch

(949) 218-0026

available from 8:00 – 4:30 MST

 

Address 841 E WILMINGTON AVE, SALT LAKE CITY, UTAH 84106 

Email SALES@SOUTHCOASTIANDC.COM

SALES@SOUTHCOASTIANDC.COM (949) 218-0026

Share on Facebook Share
Share on TwitterTweet
Print Print